Skip to content

Products and Contract Services

Maestro Imaging Systems


The standard for all-optical in vivo imaging


Award-winning Maestro™ systems (from CRi) enable in vivo fluorescence imaging of small animals with unprecedented sensitivity. Maestro provides users with a patented method of removing autofluorescence emitted from images of skin and other tissues to reveal otherwise hard-to-detect labeled targets of interest. The dramatic improvement in signal-to-noise can increase sensitivity up to several hundred-fold, enabling much smaller or fainter signals from biological targets to be detected earlier and accurately measured. The increased sensitivity over standard imaging techniques provided by Maestro’s high-quality spectral imaging technology enable experiments and models which simply cannot be performed on any other system.

The Maestro Dynamic™ system uses our patented DyCE™ (Dynamic Contrast Enhancement) technology to generate time-based kinetic images and movies of fluorescent reagents and labeled antibodies, providing quantitative data on the temporal biodistribution of fluorescent markers at much earlier time points than is possible using conventional imaging methods, and enabling better discrimination between bound and unbound antibodies. These kinetic imaging data can be used either to generate all-optical anatomic organ maps of a mouse or as a part of body-compartment modeling, pK value calculations or rate of uptake and washout determinations.

 

Upper mouse has a tumor in the left groin, revealed by an antibody bound to Alexa Fluor 680. The rest of the shaved area is non-specific signal. Lower mouse is a negative control mouse.


Sample courtesy UC-Davis Molecular Imaging Workshop
Note: Alexa Fluor® 680 is a registered trademark of the Invitrogen Corporation.



The Maestro comes in three models:


   Maestro EX  Maestro 2  Maestro Dynamic
Filter Selection  Manual  Manual  Automated
Stage Adjustment  Manual  Automated  Automated
Light-Tight Chamber  Yes  Yes   Yes 
Wavelength Range  500 - 950 nm  500 - 950 nm  500 - 950 nm
Bandwidth Selections  20 and 40 nm  20 and 40 nm  20 and 40 nm
Min Wavelength Spacing  2 nm  2 nm  2 nm
Fluorescence Sensitivity*  300x  300x  300x
CCD/Cooling  Sony ICX285 / 8° C   Sony ICX285 / 0° C    Sony ICX285 / 0° C 
Spatial Resolution  25 micron/pixel  25 micron/pixel  25 micron/pixel
Max Field-of-View  Up to 3 mice  Up to 3 mice  Up to 3 mice
Typical Exposure Time  2 - 5 sec   2 - 5 sec  2 - 5 sec
Max Exposure Time  10 min  20 min  20 min 
Anatomic Organ Maps and Kinetic Imaging  Optional  Optional  Yes  
 *Maximum sensitivity over standard monochrome imaging methods.

 


Maestro Systems