TurboVap® 500 Evaporation System
Overview
The TurboVap 500 Concentration Evaporator Workstation is a closed cell evaporation system that provides automated sample concentration and solvent recovery using a helical gas flow and sensor endpoint detection technology. The “helical flow” of air is created by a motor-driven fan. The solvent vapors rise and enter the condenser, condense on the side walls, then run out the drain into a suitable waste or reclamation container. The two position unit accommodates 500mL vessels with either 0.5 mL or 1.0 mL endpoint stems.TurboVap Family of evaporators.
Applications
Automated rapid evaporation and concentration for sample preparation prior to analysis by LC/Ms/MS and other analytical instruments.
Market and Customer Segments:
• Pharmaceutical Biotech Companies
• Clinical Laboratories
• Contract Research Organizations
• Environmental testing faculties
• Forensic and crime laboratories
• Drugs of abuse testing Facilities
• Food and Beverage companies
• Agrochemical companies
• Government and Academic Institutions
Features
• Patented vortex shearing technology
• Patented sensor endpoint detection
• Operators are free to perform more important tasks, further improving lab productivity
• No “bumping” means NO re-working of samples, saving hundreds of dollars weekly
• Solvent vapor recovery system –laboratory emissions can be greatly reduced
• Reduce facility costs by eliminating the need for a fume hood
• User Friendly Displays and Diagnostics
• Convenient Benchtop Size - no hood space required
• Patented sensor endpoint detection
• Operators are free to perform more important tasks, further improving lab productivity
• No “bumping” means NO re-working of samples, saving hundreds of dollars weekly
• Solvent vapor recovery system –laboratory emissions can be greatly reduced
• Reduce facility costs by eliminating the need for a fume hood
• User Friendly Displays and Diagnostics
• Convenient Benchtop Size - no hood space required
Specifications
Number of Samples |
|
| 2 | |
Water Bath Temperature |
|
| Ambient to 95 oC. (Upper temperature with sensors is 60 oC) | |
Timer Range |
|
| 1-99 minutes | |
Power Requirements |
|
| 110/120 VAC at 60 Hz (European, 230 VAC at 50 Hz) 900 VA max | |
Net Weight |
|
| 42 lbs. (18.6 kg) | |
Shipping Weight |
|
| 60 lbs. (27.2 kg) | |
Dimensions |
|
| 21.2” x 24” x 11.9” | |
Maximum Sample Volume |
|
| 500 mL | |
Evaporation Rate |
|
| Adjustable based on water bath temperature, fan speed and chiller or tap water temperature. (Chiller is recommended for optimum rate of evaporation and solvent reclamation.) | |
Final Endpoint Volumes |
|
| Selectable. Automatic endpoints of 0.5 mL and 1.0 mL or dryness. Easy manual intervention or timer based for other endpoints. | |
Solvent Reclamation |
|
| 95% of solvent vapors under typical conditions |