TurboVap® LV Evaporation System
Overview
The TurboVap LV Concentration Evaporator Workstation provides simultaneous evaporation of up to 50 samples. This evaporation system offers many interchangeable tube racks giving you the flexibility for automated low volume sample preparation ranging in volumes size from 1.5 mL to 30 mL. The microprocessor-control provides monitoring of the timed operation and water bath temperature. It also provides automatic gas shutoff and operational diagnostics.TurboVap Family of Concentration Evaporators.
Applications
Automated Sample Prep
Automated rapid evaporation and concentration of samples prior to analysis by LC/Ms/MS and other analytical instruments.
Market and Customer Segments:
Pharmaceutical Biotech Companies
Clinical Laboratories
Contract Research Organizations
Environmental Testing Faculties
Forensic and crime laboratories
Drugs of Abuse testing Facilities
Food and Beverage companies
Agrochemical companies
Government and Academic Institutions
Features
- Proven equivalency with EPA methods
- 10x faster than centrifugal evaporators, 3x faster than hot blocks, 2x faster than conventional N2 blow down
- Unattended operation for up to 50 samples
- Twelve racks available to accommodate a variety of tube sizes from 1.5 mL to 30 mL
- Dionex ASE-Ichem Compatible Rack, 24 positions available
- Patented Nitrogen gas vortex shearing technology
- Patented Technique Maximizes Recoveries
- Cross Contamination at Evaporation step Eliminated
- Eliminate vacuum pump and cold trap maintenance
- Controlled Waterbath is Adjustable from Ambient to 99 C
- Built-in Nitrogen Regulator
- Operators are free to perform more important tasks, further improving lab productivity
- User Friendly Displays and Diagnostics
- Convenient Benchtop Size - no hood space required
- Allows you to easily load samples and add samples once operation has begun
- Requires no tube balancing
- Allows you to easily swap racks with equal capacity for different sample containers
- No need for tools to switch rotors
- Requires no additional equipment such as vacuum pumps and vacuum traps
Specifications
Tube Capacity: 50 test tubes, rack not included, s |
|
| 10 x 75 mm tubes | up to 4 mL |
| 12 x 75 mm tubes | up to 4 mL |
| 13 x 100 mm tubes | up to 7 mL |
| 16 x 100 mm tubes | up to 12 mL |
| 16 x 125 mm tubes | up to 16 mL |
| 20 x 150 mm tubes | up to 30 mL |
| 10 mL conical bottom tubes | up to 10 mL |
| 15 mL conical bottom tubes | up to 15 mL |
| 15 mL volumetric AutoTrace tubes | up to 15 mL |
| 1.5 - 2.0 microcentrifuge tubes | 1.5 - 2.0 mL |
| 12 x 32 mm autosampler tubes | up to 15 mL |
Number of Samples |
|
| Fifty. Gas can be turned on to each of five independentmanifolds when working with fewer than fifty samples. | |
Water Bath Temperature |
|
| Ambient to 90oC. Temperatures below ambient can be regulated using the cooling capacity of the evaporation process. | |
Timer Range |
|
| 1 to 99 minutes or 0.1 to 9.9 hours -- can also be set to 00 for infinite time. | |
Gas Regulator and Gas Gauge Range |
|
| 0 to 20 psi (0 to 207 kPa) | |
Gas Supply Requirements |
|
| Minimum inlet pressure | 60 psi (413 kPa) |
| Maximum inlet pressure | 100 psi (690 kPa) |
Exhaust Port |
|
| 2" (5.1 cm) id; 12.5’ (3.8 m) of duct hose provided. | |
Power Requirements |
|
| 110/120 VAC at 60 Hz (European, 230 VAC at 50 Hz) | |
Dimensions |
|
| Height | 11.9" (30.2 cm) |
| Width | 21.2" (53.8 cm) |
| Depth | 11.9" (30.2 cm) |
Net Weight |
|
| 40.5 lbs. (18.47 kg) | |
Shipping Weight |
|
| 60 lbs. (27.2 kg) | |