Development of real-time in vivo imaging of device-related Staphylococcus epidermidis infection in mice and influence of animal immune status on susceptibility to infection

J Infect Dis

C. Vuong, S. Kocianova, J. Yu, J. L. Kadurugamuwa, M. Otto

Staphylococcus epidermidis is the leading cause of hospital-acquired device-related infections, but there is a lack of suitable methods to investigate the pathogenesis of S. epidermidis infection. We created a bioluminescent strain of S. epidermidis and developed a subcutaneous catheter-related murine infection model for real-time monitoring of biofilm-associated infection. Additionally, we compared severely immunocompromised and immunocompetent mice, demonstrating the substantial effect of animal immune status on susceptibility to experimentally induced S. epidermidis disease. This study presents a novel approach for investigating the in vivo details of the pathogenesis of S. epidermidis infection.

2008
J Infect Dis
Volume: 198. Issue: 2. Pages: 258-61.